GE Ductless Heat Pump Error Codes: Meanings & Safe Checks

Choose the code exactly as shown. Meanings and reset procedures can change across model families, display formats and markets.

E1 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies E1 as: Room-temperature sensor failure. Search/display variants: E1 caution E2 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies E2 as: Indoor-coil sensor failure. Search/display variants: E2 caution E4 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies E4 as: Indoor EEPROM error. Search/display variants: E4 caution E7 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies E7 as: Communication fault between the indoor and outdoor units. Search/display variants: E7 caution E14 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies E14 as: Indoor fan motor malfunction. Search/display variants: E14 caution F1 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F1 as: IPM protection. Search/display variants: F1 caution F2 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F2 as: Compressor overcurrent. Search/display variants: F2 stop-use F3 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F3 as: Communication fault between the IPM and outdoor PCB. Search/display variants: F3 caution F4 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F4 as: Compressor-discharge over-temperature protection. Search/display variants: F4 stop-use F6 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F6 as: Ambient-temperature sensor failure. Search/display variants: F6 caution F7 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F7 as: Suction-temperature sensor failure. Search/display variants: F7 caution F8 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F8 as: Outdoor DC fan motor fault. Search/display variants: F8 caution F11 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F11 as: Compressor deviation from normal operation. Search/display variants: F11 caution F12 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F12 as: Outdoor EEPROM error. Search/display variants: F12 caution F19 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F19 as: Power voltage is too high or too low. Search/display variants: F19 stop-use F21 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F21 as: Defrost-temperature sensor failure. Search/display variants: F21 caution F22 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F22 as: AC overcurrent protection for the outdoor unit. Search/display variants: F22 stop-use F23 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F23 as: Single-phase compressor overcurrent protection. Search/display variants: F23 stop-use F25 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F25 as: Compressor-discharge temperature sensor failure. Search/display variants: F25 caution F27 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F27 as: The compressor has a locked rotor or stopped momentarily. Search/display variants: F27 stop-use F28 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F28 as: Station detection-loop error. Search/display variants: F28 caution F36 The official GE Altitude Series Ductless Split Heat Pump Service Manual identifies F36 as: Outdoor-coil temperature sensor failure. Search/display variants: F36 caution