Pool Heater error codes

Codes are manufacturer-specific. Choose the exact brand shown on your equipment.

AC
Hayward

Official Hayward material describes AC as Blower vacuum switch closed when expected open; if the switch is closed before blower start-up, the control will not start the blower. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

AO
Hayward

Official Hayward material describes AO as The blower prover switch does not close after the blower starts; the control stops the ignition trial and goes into lockout with the blower continuing to run. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

bD
Hayward

Official Hayward material describes bD as Internal fault/power-up error. Shown on the initial trial for ignition. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

CE
Hayward

Official Hayward material describes CE as Communication error: communication between the ignition board and the display board is not established within 3 seconds of power-up, or is lost for 30 seconds after being established. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

EE
Hayward

Official Hayward material describes EE as EEPROM error: an error was detected in the ignition control circuit board. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

HF
Hayward

Official Hayward material describes HF as Flame present with the gas valve OFF; the control goes into lockout and the blower runs until the error condition is corrected. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

HS
Hayward

Official Hayward material describes HS as Water temperature sensing error: (A) the inlet water temperature sensor reports a temperature in excess of 104 degrees F; normal operation resumes 2 minutes after the sensor reports 104 degrees F or less. Or (B) the inlet sensor reports a temperature change faster than 6 degrees F in 60 seconds, indicating a…

IF
Hayward

Official Hayward material describes IF as Ignition failure: the control exceeded the maximum number of ignition retries or recycles; the heater shuts down and goes into lockout. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

IO
Hayward

Official Hayward material describes IO as Igniter open error: the igniter circuit is sensed open while the blower is running (when not in lockout); the control turns off the blower and goes into lockout. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

LO
Hayward

Official Hayward material describes LO as Limit string open error: if the limit string opens, the heater shuts down and goes into lockout. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

PF
Hayward

Official Hayward material describes PF as Electrical supply wiring error: displays if 120V polarity is reversed, low voltage is detected, or the ground path is not sufficient. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

Sb
Hayward

Official Hayward material describes Sb as Keypad button stuck closed: one of the keypad buttons is closed (or pressed) for more than 30 seconds; the error code displays but the control continues to function. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

SF
Hayward

Official Hayward material describes SF as Thermistor error: an excessive temperature difference between the two thermistors (5 degrees F or more), or an 'out of bounds' condition on both sensors (less than 10 degrees F or greater than 180 degrees F). This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

126
Pentair

Official Pentair material describes 126 as Shorted water temperature sensor. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

E01
Pentair

Official Pentair material describes E01 as Open water temperature sensor. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

E05
Pentair

Official Pentair material describes E05 as Open stack flue sensor. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

E06
Pentair

Official Pentair material describes E06 as Shorted stack flue sensor. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

ERR AFS
Pentair

Official Pentair material describes ERR AFS as Air flow switch open: the blower is not on, or air through it is being restricted. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

ERR AGS
Pentair

Official Pentair material describes ERR AGS as Automatic gas shutoff: water temperature after the second pass through the heat exchanger is more than 140 degrees F. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

ERR HLS
Pentair

Official Pentair material describes ERR HLS as Hi temperature limit switch open: water temperature after the first pass through the heater exchanger is more than 135 degrees F. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

ERR IGN
Pentair

Official Pentair material describes ERR IGN as Ignition Control Module was not able to ignite the heater. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

ERR PS
Pentair

Official Pentair material describes ERR PS as Water pressure switch open: no water flow through the heater. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.

ERR SFS
Pentair

Official Pentair material describes ERR SFS as Excessive stack flue temperature: the temperature of the stack flue is more than 480 degrees F. This guide records the cited product-family scope, safety-reviewed owner checks, and service limits.